Multifunctional Gate Box
Search by features
Multifunctional Gate Box
MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.
EUCHNER Locking module MGB-L1-ARA-AM5A1-S1-L-121217; 121217
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1HE-ARA-R-121189; 121189
Locking set MGB-L1HE-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Interlocking module MGB-L0-APA-AA1A2-S1-L-112598 ; 112598
Interlocking module MGB-L0-APA..., without controls or indicators, RC18, on mounting plates Interlocking (without guard locking) With plug connector RC18 Mounted
-

(Out of stock)
Price on request
EUCHNER Interlocking module MGB-L0-ARA-AA1A1-S1-L-111941; 111941
Interlocking module MGB-L0-ARA..., without control or indicator, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AL3A1-S8-R-157884; 157884
Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-L-121422; 121422
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, IP54 Guard locking with guard lock monitoring Can be connected
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-L-121068; 121068
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons Guard locking with guard lock monitoring Can be connected in series with other AR devices
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-L-110871; 110871
Locking set MGB-L1H-ARA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L2H-APA-R-110548; 110548
Locking set MGB-L2H-APA... (guard locking by solenoid force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-ARA-BA1A1-M-109945; 109945
Locking module MGB-L2-ARA... (guard locking by solenoid force) without control or indicator, guard lock monitoring switched off Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER HANDLE MODULE WITH LOCKOUT BAR MGB-H-AA1A7-R-113201; 113201
HANDLE MODULE WITH LOCKOUT BAR MGB-H-AA1A7-R-113201; 113201
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-ARA-AA1A1-S1-L-111943; 111943
Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators, RC18 Guard locking with guard lock monitoring Can be connected in series
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-ARA-L-110614; 110614
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-APA-AB6A1-S1-L-110076; 110076
Locking module MGB-L2-APA.. (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-ARA-AL2A1-M-R-121172; 121172
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, incl. label carrier Guard locking with guard lock monitoring Can be connected
-

(Out of stock)
Price on request
Multifunctional Gate Box
The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.
Economical, standard-compliant wiring
The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.
Seamless integration by means of bus connection
In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.